Skip to content

Manikin & ID Settings

This screen sets a name and an ID (color + number) for each manikin. The manikin list, the measurement cards, and the results show the same name and ID, so you can tell the manikins on the screen and in the training room apart when you use several at once.

In the app, it is called Color ID. It consists of one color + a number from 0 to 99.

7 colorsGray (no color), red, green, yellow, blue, pink, and purple.
On-screen displayThe manikin list, the measurement cards, and the results use this circle to tell the manikins apart.
Number 0 · no colorIf the number is 0, only the color is shown, with no number. No color is a gray circle with a gray number.

Select the gear Settings button at the top right of the Home screen, then select Manikin & ID Settings. For the whole Settings screen, see Other settings.

1

Only the manikins you selected in Manikin connection are shown. They are sorted by ID (color → number).

Manikin & ID Settings1Manikin A2Manikin B1Manikin C25%1234
  1. 1Battery icon: Hover over it to see the remaining charge (%). It turns yellow below 30% and red below 10%, so even when it is green, check the number before class and replace the batteries ahead of time.
  2. 2› button: Opens the Manikin Info screen for that manikin.
  3. 3Grayed-out row: A manikin that is disconnected. Its info screen does not open.
  4. 4Search: Goes to the manikin search screen to connect more manikins.
2
Manikin InfoConnected1Manikin ALittle AnneManikin NameColor ID1ManikinKit NumberKit VersionManikin ATap here to changeLittle Anne | CPR Add-on Kit (Gen 3)A1B2C3D41.2.712345
  1. 1Summary: Shows the connection status (Connected / Unavailable), the ID, the name, and the manikin type.
  2. 2Manikin Name: Select the pencil button or the card to open the name change window (step 3).
  3. 3Color ID: Select the color circle or the card to open the ID change window (step 4).
  4. 4Manikin: The type of manikin the kit is fitted to. Only a CPR Add-on Kit has a pencil button, so only then can you change it (step 5).
  5. 5Kit Number and Kit Version: View only. Please include them when you contact contact@imlabworld.com.
3
Manikin InfoConnected1Manikin ALittle AnneManikin NameColor ID1ManikinKit NumberKit VersionManikin ATap here to changeLittle Anne | CPR Add-on Kit (Gen 3)A1B2C3D41.2.7Rename ManikinPlease enter a new manikin name.Room 1-Manikin14/15 bytesCancelRename12
  1. 1Byte count: A name can be up to 15 bytes. English letters and digits take 1 byte each, accented letters such as é or ü take 2 bytes, and Korean, Japanese, or Chinese characters take 3 bytes. That allows 15 English letters or digits, 7 accented letters, or 5 Korean, Japanese, or Chinese characters.
  2. 2Rename: Enabled once you enter at least 2 characters. The window closes automatically when the change is done.
4
Manikin InfoConnected1Manikin ALittle AnneManikin NameColor ID1ManikinKit NumberKit VersionManikin ATap here to changeLittle Anne | CPR Add-on Kit (Gen 3)A1B2C3D41.2.7Change Color ID33Color TagCancelChange1234
  1. 1Preview: Shows the new ID.
  2. 2Number: Use the arrows to change it one at a time, or type the number directly. You can enter 0–99.
  3. 3Color Tag: Select a color.
  4. 4Change: Applies the change. When it is done, the window closes automatically and the list is sorted in the new order.
5

Select the Manikin card in step 2 to open this window.

Manikin InfoConnected1Manikin ALittle AnneManikin NameColor ID1ManikinKit NumberKit VersionManikin ATap here to changeLittle Anne | CPR Add-on Kit (Gen 3)A1B2C3D41.2.7Change ManikinAmbu SamAmbuLittle AnneLaerdalBraydenInnosonianNurugoBestCPROther ManikinsCancelChange123
  1. 1Manikin options: Select the manikin the kit is fitted to.
  2. 2Other Manikins: If it is not listed, select this to find it in the lists by manufacturer. Select the ← button in the title bar to go back to the first screen.
  3. 3Change: Applies the change. Enabled once you select a manikin.

The manikins you can select depend on the kit type and kit version, so the first screen may not show all 4 types.

It only says “No manikin connected.”

No manikins are connected. Select the Search button at the bottom right and connect the manikins first. (Manikin connection)

A manikin row is grayed out and I can’t select it

That manikin is disconnected. Check the power and the batteries, then connect it again. If it disconnects while you are viewing its info screen, the summary shows Unavailable and you cannot change anything.

The error message “Failed to rename.” / “Failed to change the color ID.” / “Failed to change the manikin.” appears

The change could not be saved on the manikin. Check that the summary shows Connected, move the manikin closer to the PC, and try again.

I can’t select the Rename button

It is grayed out while the name is empty or only 1 character long. If you enter only 1 character, “Please enter at least 2 characters” is shown below the field. Enter at least 2 characters.

I can’t enter any more of the name

The manikin stores a name of up to 15 bytes. That is 15 English letters or digits (1 byte each), 7 accented letters (2 bytes each), or 5 Korean, Japanese, or Chinese characters (3 bytes each). Mixing in English letters or digits allows a longer name (example: 6 accented letters + 3 digits = 15 bytes).

With a composing input method (Korean, Japanese, or Chinese), the count may briefly go over 15 while you type. When you finish the character, any characters beyond 15 bytes are removed.

The Manikin card has no pencil button

That manikin does not use a CPR Add-on Kit. Its manikin type is fixed, so you cannot change it.

The battery icon is red

Less than 10% is left. Replace the batteries right away. (Troubleshooting)