Assessment Settings
Set the standards the app uses to judge and score students’ compressions and breaths. The compression depth and breath volume ranges depend on the guideline and the target patient (adult, child, or infant). You also set here which items count toward the score.
Menu location
Section titled “Menu location”Select the gear Settings button at the top right of the Home screen, then select Assessment Settings. In Feedback Mode, selecting More settings in the Quick Settings window also opens the Settings screen. (Feedback Mode)
How to use
Section titled “How to use”Assessment Settings screen
Section titled “Assessment Settings screen”The value currently selected is shown in parentheses next to each item name.
- 1Reset: Returns all assessment settings to their defaults. (step 6)
- 2Guideline: Selects the guideline used as the scoring standard. (step 2)
- 3Compression Rate Guide: Selects the metronome speed (BPM). (step 3)
- 4Target Patient Mode: Selects the target patient for each manikin type. (step 4)
- 5Scoring / CPR Mode: Sets the CPR mode and the items that count toward the score. (step 5)
Guideline selection
Section titled “Guideline selection”- 1Select the guideline you want to use. The default is AHA 2025.
- 2Your choice is saved only when you select Confirm. If you select Cancel, nothing changes.
Normal compression depth ranges by guideline and target patient:
| Guideline | Adult | Child | Infant |
|---|---|---|---|
| AHA 2025 · Heart & Stroke 2025 · ERC 2025 | 5–6 cm | At least 5 cm | At least 4 cm |
| Canadian Red Cross 2025 | 5–6 cm | At least 5 cm | At least 4 cm |
| KACPR 2025 | 5–6 cm | At least 4 cm | At least 4 cm |
| ANZCOR(ARC) 2026 | 5–7 cm | At least 5 cm | At least 4 cm |
| SRFAC 2021 | 4–6 cm | At least 4 cm | At least 3 cm |
Compressions that are too deep are also shown in red.
Normal breath volume ranges when breaths are turned on:
| Guideline | Adult · Child | Infant |
|---|---|---|
| All except SRFAC 2021 | 400–600 mL | 50–70 mL |
| SRFAC 2021 | 400–600 mL | 30–50 mL |
Compression Rate Guide selection
Section titled “Compression Rate Guide selection”- 1Select 100, 110, or 120 BPM. The default is 110 BPM.
- 2Your choice is saved only when you select Confirm.
This is the beat speed that plays in Feedback Mode when the metronome is on. The scoring standard (100–120 per minute) does not change.
This is the same setting as Compression Rate Guide → Speed in the Feedback Mode Quick Settings window. If you change it in one place, it changes in the other too.
Target Patient Mode selection
Section titled “Target Patient Mode selection”When expanded, the manikin types currently connected are shown, one per row.
- 1Select the Target Patient Mode row to expand or collapse it.
- 2Select the manikin type you want to change. All manikins of the same type change together.
- 3Current target patient: ADULT = Adult, CHILD = Child, INFANT = Infant.
- 1Select Adult, Child, or Infant.
- 2Grayed-out options are target patients the manikin does not support, so you cannot select them.
- 3Your choice is saved only when you select Confirm.
Target patients you can select for each manikin, and their defaults:
| Manikin (name shown in the app) | Target patients you can select | Default |
|---|---|---|
| Basic Buddy+ · BASICBilly+ · cprCUBE PRO · CPR Prompt+ | Adult, Child | Adult |
| Ambu Junior · Little Junior | Child | Child |
| Ambu Baby · Baby Buddy+ · Prompt Infant+ · Jana · Little Baby | Infant | Infant |
| Other manikins (Little Anne, Brayden, etc.) | Adult | Adult |
Scoring and CPR mode settings
Section titled “Scoring and CPR mode settings”- 1Breath: Sets the CPR mode. Off means Hands-only CPR (compressions only), and on means Conventional CPR (compressions + rescue breathing). It is off by default. Compression just above it is always on and cannot be changed.
- 2Compression:Breath Score Weight: Drag the slider to set how much compressions and breaths each count toward the score. It adjusts in 5% steps, between 5% and 95% for compressions. It is grayed out when breaths are off.
- 3If you turn off Rate or Recoil, that item does not count toward the compression score. Depth is always on and cannot be changed.
- 4You cannot change Breath Volume directly. It turns on and off with the Breath switch above.
- 5Hands-off Time: When on, the longer compressions stop, the more points are deducted from the total score. When off, no points are deducted.
Example: if you measure Conventional CPR with the defaults (compression 75% / breath 25%), the score card shows compressions out of “/75” and breaths out of “/25”.
Assessment settings reset
Section titled “Assessment settings reset”Select Reset at the top right to show a confirmation window.
- 1Select Reset to return to the defaults below. If you select Cancel, nothing changes.
| Item | Default |
|---|---|
| Guideline | AHA 2025 |
| Compression Rate Guide | 110 BPM |
| Target Patient Mode | Default for each manikin type (table above) |
| CPR Mode | Hands-only CPR (breaths off) |
| Compression:Breath Score Weight | Compression 75% / Breath 25% |
| Rate · Recoil · Hands-off Time | All on |
| Feedback Mode metronome (Compression Rate Guide switch) | On |
| Mission Mode Session Time Limit | 1 min |
| Mission Mode “End the session when the first person reaches 100%” | Off |
Frequently asked questions
Section titled “Frequently asked questions”I selected Target Patient Mode and it says “No manikin connected.”
The target patient is set for each connected manikin type, so it cannot be set when no manikin is connected. Connect a manikin first, then select it again. (Manikin connection)
Child (or Infant) is grayed out and I can’t select it
The connected manikin does not support that target patient. You can select child only when Basic Buddy+, BASICBilly+, cprCUBE PRO, CPR Prompt+, Ambu Junior, or Little Junior is connected, and infant only when Ambu Baby, Baby Buddy+, Prompt Infant+, Jana, or Little Baby is connected. The full list by manikin is in the “Target patients you can select” table above.
The score weight slider won’t move
When the Breath switch is off (Hands-only CPR), the slider is grayed out. Turn on breaths to adjust it.
If I change the Compression Rate Guide, does the scoring standard change too?
No, only the metronome beat speed changes. The compression rate standard is always 100–120 per minute.
I switched to Conventional CPR, but there’s no breath score
Manikins that cannot measure breaths are scored on compressions only. Check whether the manikin has a breath module.
Settings won’t open on the student tablet